Amana AC Repair in Greenville done right the first time
Certified Amana air conditioner repair in Greenville SC, same day
When your Amana system quits, you need Amana AC Repair in Greenville that actually fixes the cause, not just the symptom. We service every Amana model, from older units running R-22 to current R-410A systems, and we carry the run capacitors, contactors, and blower motors that fail most often in Greenville's heat. Same-day Amana air conditioner repair Greenville SC is available across Greenville County.
What Amana AC Repair in Greenville actually involves
Amana AC Repair in Greenville is the diagnostic and mechanical work that restores an Amana air conditioner or heat pump to full cooling capacity, and it is needed whenever the system stops cooling, short cycles, leaks water, or trips the breaker. In practice that means testing the run capacitor and contactor, checking refrigerant charge with a manifold gauge set, verifying airflow across the evaporator coil, and confirming the thermostat is calling correctly. Amana units share most parts with Goodman, so we keep common components on the truck.
Greenville summers push condensers hard. July and August afternoons sit in the mid-90s with high humidity, and a system that was marginal in May fails in July. Most calls we run in Greenville County come down to a weak run capacitor, a pitted contactor, a clogged condensate drain line, or a slow refrigerant leak. If you search Amana AC repair near me Greenville SC on a 95-degree afternoon, you are usually looking at one of those four.
Why Greenville homeowners call us for Amana
Amana equipment is reliable, but it is not immune to South Carolina heat and humidity. Here is what you get when you book Amana AC service Greenville South Carolina through our team.
Same-day service available
We hold same-day Amana AC repair Greenville SC slots open every weekday for no-cool calls. Most diagnostics take 45 to 60 minutes, and roughly 8 out of 10 repairs are finished on that first visit because we stock Amana-matched capacitors, contactors, and blower motors on the truck.
Certified Amana technicians
Every tech on our crew holds EPA Section 608 certification and NATE certification, and we follow manufacturer charging charts rather than guessing. That matters on Amana units, where an overcharge of even 4 ounces can raise head pressure and shorten compressor life.
Upfront pricing, no surprises
You get the diagnostic result and a flat price before we open a single tool bag. Typical 2026 Amana AC repair in Greenville runs $180 to $650 for common failures, and we tell you which repairs are worth doing on a unit past 12 years old.
Parts kept in stock
We carry run capacitors, start capacitors, contactors, condenser fan motors, and drain pan tablets for Amana and Goodman platforms. That is why a capacitor replacement is usually a 30-minute job instead of a two-day wait for a parts order.
How our Amana AC repair process works
You get a clear sequence from the first phone call to the final temperature check. No mystery, no waiting around all day for a window.
Book the call
Call (903) 627-1334 or book online. We ask for your Amana model number, the symptom, and your ZIP code so we can route the closest truck. Most Greenville addresses get a two-hour arrival window, and same-day slots are held for no-cool emergencies.
Diagnose the system
The tech checks thermostat operation, then reads amp draw at the compressor and condenser fan motor with a clamp meter. A manifold gauge set gives us suction and liquid pressures, and a multimeter confirms capacitor microfarads against the Amana spec printed on the label.
Explain findings and price
You get the diagnosis in plain language plus a flat repair price. If the issue is a $220 capacitor, we say so. If the compressor is grounded and the unit is 14 years old, we tell you that too, and what a replacement would cost instead.
Complete the repair
We replace the failed part, then leak-test with an electronic leak detector and pull a proper vacuum with a vacuum pump before any recharge. Refrigerant is recovered with a recovery machine and handled under EPA Section 608 rules. Most repairs finish in 60 to 90 minutes.
Test and verify
We run the system for at least 15 minutes and measure supply-air temperature. A healthy Amana split in Greenville should deliver air 18 to 22 degrees cooler than the return. We also flush the condensate drain line and confirm the drain pan is dry before we leave.
Local experience with Amana systems
Our technicians work on Amana equipment every week, alongside Carrier, Trane, Lennox, Goodman, Rheem, York, American Standard, Daikin, Mitsubishi Electric, Bryant, and Payne systems. That cross-brand exposure matters, because Amana shares its Goodman-built platform with several of those units. We hold EPA Section 608 certification, NATE certification, and an SC HVAC contractor license, and we work to ACCA installation and airflow standards on every job. We also carry the Greenville County business license required to operate here. When a system is under a manufacturer parts warranty, we document the failure properly so the claim goes through.
- EPA Section 608 certified for refrigerant recovery, recharge, and leak repair on R-410A, R-32, and legacy R-22 systems.
- NATE-certified technicians who test capacitor microfarads and compressor amp draw against Amana factory specs.
- SC HVAC contractor license and Greenville County business license on file for every job we run.
- ACCA-based airflow and static pressure checks to catch duct problems that mimic Amana equipment failures.
- Electronic leak detection and nitrogen pressure testing before any refrigerant is added to your system.
Why choose us for Amana AC Repair in Greenville
We are a local crew, not a call center. The person who answers the phone can tell you what a failing Amana contactor sounds like, and the tech who shows up has the parts to fix it.
Real diagnostic, not guesswork
We test before we replace. Amp draw, capacitor microfarads, superheat, and subcooling get measured on every call, so you are not paying for a part that was never the problem. Roughly one in five 'bad compressor' calls we run turns out to be a $40 contactor or a failed start capacitor.
Amana parts on the truck
Run capacitors, start capacitors, contactors, condenser fan motors, and thermostats for Amana and Goodman units ride with us daily. That is the difference between a 30-minute fix and a two-day wait in August.
Honest repair-or-replace advice
If your Amana unit is 12 years or older and facing a compressor or evaporator coil replacement, we will show you the numbers on both paths. We do not push replacement when a $300 repair buys you another four or five summers.
Clean, respectful service
Drop cloths under the air handler, shoe covers on hardwood, and a full cleanup before we leave. We also walk you through the filter size and change interval your Amana system needs, which is the single cheapest way to avoid repeat breakdowns.
What our Amana AC repair includes
Every Amana AC fix Greenville call includes a full diagnostic, not just the part swap. Here is what is covered in a standard repair visit, and what we quote separately if your system needs it.
What's Included
Full system diagnostic
Thermostat verification, capacitor and contactor testing, compressor amp draw, refrigerant pressures, and airflow check. This is where we find the actual cause instead of replacing parts until something works.
Failed part replacement
Run capacitor, start capacitor, contactor, blower motor, condenser fan motor, or thermostat, installed and tested. We match the part rating to your Amana model rather than dropping in whatever fits.
Refrigerant leak search
Electronic leak detector sweep of the evaporator coil, line set, and service valves, followed by nitrogen pressure testing on stubborn leaks. We locate the leak before we discuss a recharge.
Condensate drain service
We flush the condensate drain line, clear the trap, and add drain pan tablets to slow algae growth. A clogged drain line is one of the most common reasons an Amana system shuts down on a humid Greenville day.
Air filter and airflow check
We inspect the filter, check static pressure, and confirm the evaporator coil is not restricted. A dirty filter or blocked coil can freeze the evaporator and make a healthy Amana unit look like it needs major work.
Amana problems we fix in Greenville
These are the calls we run most often on Amana systems around Greenville County. Each one has a known cause and a straightforward fix.
Amana AC not cooling and blowing warm air
Supply air climbs above 70 degrees, the house never catches up, and the compressor runs continuously, driving up your power bill while the indoor temperature climbs.
We check capacitor microfarads, contactor condition, and refrigerant charge in that order. A weak run capacitor is the most common cause, and a replacement typically restores full cooling in under an hour. If pressures are low, we leak-test before adding refrigerant.
Amana AC short cycling on and off
Short cycles wear the compressor and contactor faster, raise humidity indoors, and can trip the breaker repeatedly until the system stops starting altogether.
Short cycling usually traces to an oversized system, a failing thermostat, or a refrigerant charge issue. We verify thermostat calibration, check superheat and subcooling, and confirm the contactor is not pitted. Most short-cycle repairs land between $180 and $420.
Amana AC leaking water around the air handler
Water stains ceilings, warps flooring, and can trip the float switch, shutting the system down on the hottest day of the year.
We flush the condensate drain line, clear the trap, and check the drain pan for cracks. If the evaporator coil is iced over, we thaw it, verify airflow, and confirm the coil is clean. Drain line clogs are usually a same-visit fix.
Amana AC not turning on at all
No fan, no cooling, and a house that heats up fast in a Greenville afternoon. Often the breaker has tripped or the float switch has cut power.
We check the breaker, the float switch, the contactor, and the transformer in sequence. A failed contactor or blown low-voltage fuse is common and inexpensive to fix. If the compressor is grounded, we show you the amp readings and lay out your options.
When to call for Amana AC repair
A homeowner in Nicholtown notices the Amana unit running but the house sitting at 79 degrees on a 96-degree afternoon.
We diagnose on arrival, find a run capacitor reading 18 microfarads against a 35-microfarad spec, and replace it with an Amana-matched capacitor. We then verify supply-air temperature and refrigerant pressures before leaving.
Cooling restored the same afternoon, with supply air 20 degrees cooler than return and the compressor drawing normal amps again.
A rental property owner near Furman has a tenant reporting water on the closet floor under the air handler.
We clear the condensate drain line, flush the trap, replace a cracked drain pan fitting, and add drain pan tablets. We also check the float switch and confirm it is working.
Dry closet floor, working safety switch, and a tenant who stops calling. Total visit ran about 75 minutes.
An office manager on Haywood Road has an Amana rooftop unit short cycling every four minutes during business hours.
We test thermostat calibration, check the contactor for pitting, and measure superheat and subcooling. The fix was a failed contactor plus a low refrigerant charge traced to a Schrader valve leak.
Cycle time returned to normal, and the space held 72 degrees through the afternoon without the breaker tripping.
A homeowner in Berea with a 13-year-old Amana unit hears a grinding noise from the outdoor condenser fan.
We shut the unit down, inspect the condenser fan motor, and find worn bearings. We replace the motor, clean the condenser coil with a coil cleaning pump sprayer, and straighten bent fins with a fin comb.
Quiet operation restored, condenser coil airflow improved, and head pressure dropped into the normal range for a 95-degree day.
Tools and methods we use on Amana systems
Tools & Equipment
Manifold gauge set
Reads suction and liquid line pressures so we can calculate superheat and subcooling and confirm the Amana charge is correct rather than guessing by feel.
Clamp meter and multimeter
Measures compressor and fan motor amp draw and tests capacitor microfarads, contactor continuity, and low-voltage control circuits.
Vacuum pump and recovery machine
Recovers refrigerant under EPA Section 608 rules and pulls a deep vacuum before recharge, which removes moisture that destroys compressors.
Electronic leak detector
Finds refrigerant leaks at the evaporator coil, line set, and service valves so we repair the source instead of repeatedly topping off the charge.
Coil cleaning pump sprayer and fin comb
Cleans condenser and evaporator coils and straightens bent fins, restoring airflow that Greenville pollen and cottonwood steadily block.
Torch kit, tube cutter, and flaring tool
Used for brazing line set repairs and fabricating flare connections when a leaking joint or damaged tubing needs replacement.
Methods & Techniques
Superheat and subcooling verification
We calculate both values against the Amana charging chart for the outdoor temperature and indoor wet-bulb. This catches undercharge and overcharge that a pressure reading alone would miss, and it protects the compressor from slugging.
Capacitor microfarad testing
A capacitor that reads more than 6 percent below its rated microfarads is failing, even if the unit still starts. We test every run and start capacitor we touch and replace them before they take the compressor with them.
Nitrogen pressure testing
When an electronic leak detector flags a coil or line set, we isolate the circuit and pressurize with dry nitrogen. It holds pressure or it does not, which tells us exactly where the leak lives.
Static pressure and airflow measurement
We measure return and supply static pressure to confirm the blower is moving the CFM the Amana system needs. Restricted airflow freezes evaporator coils and mimics refrigerant problems.
How Amana AC repair runs in Greenville
Greenville's climate is the whole story here. We run 90-plus-degree afternoons from June through September with humidity that keeps condensate drains working overtime. Older homes in Nicholtown, Sterling, and Overbrook often have undersized return ducts and attic air handlers, which pushes static pressure high and freezes evaporator coils. Newer builds out toward Berea and Monaghan usually have better ductwork but still see condenser coils packed with pollen and cottonwood by mid-May. On the refrigerant side, we still find R-22 Amana units in Greenville, and those get handled differently than R-410A or R-32 systems because of supply and EPA Section 608 rules. If you need Amana air conditioner repair in Greenville South Carolina during a heat wave, call early. Morning slots go first, and an attic air handler at 2 p.m. in July is a genuinely rough place to work. We also see a spike in Amana AC not cooling repair Greenville calls right after the first 95-degree week, when marginal capacitors finally give out.
Service Areas
Older housing stock with attic air handlers and undersized returns. Frozen evaporator coils show up here more than anywhere else we service.
Mix of renovated older homes and new construction. Duct modifications during remodels often leave static pressure higher than the Amana blower was sized for.
Larger lots mean longer line sets and more shade trees. Leaf debris and pollen clog condenser coils fast, so spring coil cleaning pays off here.
Condos and tight mechanical closets. Limited airflow around the air handler makes drain line clogs and float-switch trips common calls.
Higher elevation and more tree cover. We see condenser coils packed with debris and occasional rodent damage to low-voltage wiring.
Local Considerations
Long, humid cooling season from May through September
Condensate drain lines grow algae quickly, so we flush and treat drains on nearly every Amana repair call. A clogged line trips the float switch and shuts the system down.
Heavy spring pollen and cottonwood
Condenser coils clog by mid-May, raising head pressure and reducing capacity. We clean coils with a pump sprayer and straighten fins with a fin comb to restore airflow.
Attic-mounted air handlers in older neighborhoods
Attic temperatures above 130 degrees stress capacitors and blower motors. We test microfarads and amp draw carefully on these systems because heat-related failures are common.
Legacy R-22 Amana units still in service
R-22 supply is limited and expensive, so we leak-test thoroughly before recommending a recharge. Often a repair or replacement decision makes more sense than repeated top-offs.
Capacitor failure in Nicholtown
A 9-year-old Amana unit ran continuously but the house sat at 79 degrees on a 96-degree afternoon. The compressor was drawing high amps and the outdoor fan was slow to start.
We replaced a run capacitor reading 18 microfarads against a 35-microfarad spec. Supply air dropped to 20 degrees below return within 20 minutes, and compressor amp draw returned to nameplate range.
Maintenance & Follow-up
Test capacitor microfarads every spring. A $220 capacitor replacement now prevents a compressor failure that would run $1,400 or more.
A condo owner found water in the mechanical closet and the Amana system shut off overnight. The float switch had tripped, and the drain pan was full.
We flushed the condensate drain line, cleared the trap, replaced a cracked pan fitting, and added drain pan tablets. The float switch tested good and the closet stayed dry through a week of humid weather.
Maintenance & Follow-up
Pour a cup of vinegar down the drain line every month during cooling season and keep drain pan tablets fresh.
A 13-year-old Amana condenser made a grinding noise and the breaker tripped twice in one week. Head pressure was climbing and the coil was packed with debris.
We replaced the condenser fan motor, cleaned the coil with a coil cleaning pump sprayer, and straightened bent fins with a fin comb. Head pressure dropped into normal range and the breaker stopped tripping.
Maintenance & Follow-up
Hose off the condenser coil each spring and check the fan motor for bearing noise before the first 90-degree week.
What Amana AC repair costs in Greenville
Typical 2026 pricing for Amana AC repair in Greenville runs $180 to $650 for common failures, with compressor or coil replacements reaching $1,200 to $2,400. Diagnostic visits are quoted upfront, and the price you hear is the price you pay. What moves the number is the part involved, refrigerant work, and how accessible the air handler is. A capacitor swap is quick and cheap. A sealed-system leak search takes longer and costs more, but it is the only way to fix the problem instead of refilling it.
Pricing Factors
Failed component type
A run capacitor or contactor is a fast, low-cost repair. A blower motor, condenser fan motor, or compressor costs more because of the part price and labor time.
Refrigerant work required
Leak detection, recovery, and recharge add cost, and R-22 is far more expensive per pound than R-410A or R-32. We always leak-test before recharging.
Access to the air handler
Attic and tight-closet installations in older Greenville neighborhoods take longer to work in than a garage or closet unit with clear access.
System age and condition
On a unit past 12 years, we weigh repair cost against remaining life. Sometimes a $400 repair is smart; sometimes it is money into a system that is near the end.
Duct and airflow issues
Restricted returns or a dirty evaporator coil can cause symptoms that look like equipment failure. Cleaning and airflow correction may be part of the fix.
Typical Investment Range
$180 - $650 for most repairs; $1,200 - $2,400 for compressor or coil replacement
Actual pricing varies based on project scope and requirements
Value You Receive
You get a measured diagnosis, a matched Amana part, and a system tested to real temperature and pressure numbers before we leave. That is what keeps the repair from repeating next summer.
Frequently Asked Questions
Have questions? We have answers. If you don't see your question here, feel free to contact us.
Call UsHow much does Amana AC repair cost in Greenville SC?
Most Amana AC repairs in Greenville run $180 to $650 in 2026, with capacitor and contactor replacements at the low end and blower or condenser fan motors higher. Compressor or evaporator coil replacement runs $1,200 to $2,400. Refrigerant work and attic access add cost. We quote the repair price after diagnosis, before any work starts.
Who repairs Amana air conditioners in Greenville?
We do. Greenville AC Repair Pros services Amana systems across Greenville County, from Downtown and the West End to Berea, Parker, and Monaghan. Our technicians hold EPA Section 608 and NATE certification and carry Amana-matched capacitors, contactors, and fan motors on the truck, so most repairs finish on the first visit.
Are you certified for Amana AC repair in Greenville South Carolina?
Yes. Our team holds EPA Section 608 certification for refrigerant handling, NATE certification for HVAC service, an SC HVAC contractor license, and a Greenville County business license. We also work to ACCA airflow standards and follow Amana charging charts on every R-410A, R-32, or legacy R-22 system we service.
Why is my Amana AC not cooling in Greenville?
In Greenville, the usual causes are a weak run capacitor, a pitted contactor, a clogged condensate drain tripping the float switch, or a slow refrigerant leak. High humidity and 95-degree afternoons push marginal parts over the edge. We test capacitor microfarads, amp draw, and refrigerant pressures to find the real cause.
Licensed, certified, and reviewed
Certifications
Customer Reviews
Our Amana stopped cooling on a Saturday in July and they had a tech out by 2 p.m. Turned out to be a run capacitor. He showed me the meter reading, replaced it, and the house was cool again in an hour. Fair price and no upsell.
Water was pooling under our air handler in the West End. They cleared the drain line, replaced a cracked fitting, and added tablets. Explained how to keep it from happening again. Clean work and they wore shoe covers.
Our Amana was short cycling and another company told us we needed a new compressor. These guys tested everything and found a bad contactor and a small leak at a Schrader valve. Fixed both for a fraction of the quote.
Grinding noise from the outdoor unit in Berea. They replaced the condenser fan motor, cleaned the coil, and straightened the fins. Head pressure dropped right back to normal. Honest, fast, and they cleaned up after themselves.
Related Services
Explore our other professional services
Central AC Repair
Central systems share the same capacitors, contactors, and airflow issues we see on Amana units. If your Amana is a central split system, this is the same service with the same diagnostic process and parts stock.
Central AC RepairEmergency AC Repair
When your Amana quits on a 98-degree Greenville afternoon, emergency service gets a tech out fast. We prioritize no-cool calls and carry the parts that cause most sudden failures.
Emergency AC RepairSame-Day AC Repair
We hold same-day slots for Amana no-cool calls across Greenville County. Most diagnostics take under an hour, and roughly 8 in 10 repairs finish the same visit.
Same-Day AC RepairResidential AC Repair
Most Amana systems we service are residential splits and heat pumps in Greenville homes. This covers attic air handlers, garage condensers, and everything in between.
Residential AC RepairCommercial AC Repair
Amana rooftop and light commercial units get the same diagnostic approach, with scheduling built around your business hours so we are not shutting down your space mid-day.
Commercial AC RepairDuctless Mini-Split AC Repair
Amana and other ductless heads need coil cleaning and refrigerant checks just like central systems. We service mini-splits in Greenville condos and additions where ductwork is not an option.
Ductless Mini-Split AC RepairHeat Pump Repair
Many Amana systems are heat pumps, which means the same reversing valve, defrost board, and charge issues apply. We service both cooling and heating modes in one visit.
Heat Pump RepairCarrier AC Repair
Carrier systems use similar components to Amana, and our techs work both brands weekly. If you have a Carrier unit, the diagnostic process and parts stock look the same.
Carrier AC RepairTrane AC Repair
Trane equipment has its own charging characteristics. We service Trane alongside Amana and follow the manufacturer chart for each brand rather than a generic target.
Trane AC RepairLennox AC Repair
Lennox units, including variable-capacity models, get the same measured approach. We test capacitors, contactors, and refrigerant charge against Lennox specs.
Lennox AC RepairGoodman AC Repair
Amana and Goodman share a platform, so many parts interchange. If you have a Goodman unit, we likely already have the capacitor or contactor on the truck.
Goodman AC RepairRheem AC Repair
Rheem systems show up across Greenville in both older and newer homes. We handle refrigerant, electrical, and airflow repairs on Rheem equipment the same way we do Amana.
Rheem AC RepairYork AC Repair
York units have their own control and charging quirks. Our techs work on York systems regularly and carry common parts that fit both York and Amana platforms.
York AC RepairAmerican Standard AC Repair
American Standard equipment shares design lineage with Trane. We service both brands and apply the correct charging chart for each system we touch.
American Standard AC RepairAC Compressor Repair
A grounded or seized compressor is the worst-case Amana failure. We confirm with amp draw and insulation testing before recommending replacement, so you are not sold a compressor you do not need.
AC Compressor RepairAC Condenser Repair
Condenser fan motors, coils, and contactors fail often in Greenville heat. We clean coils, replace fan motors, and straighten fins to restore airflow and head pressure.
AC Condenser RepairAC Evaporator Coil Repair
Evaporator coils leak and freeze. We leak-test with an electronic detector, thaw frozen coils, and correct the airflow problems that cause freezing in the first place.
AC Evaporator Coil RepairAC Fan Motor Repair
Grinding or slow fan motors raise head pressure and trip breakers. We replace condenser and blower motors with matched parts and verify amp draw after installation.
AC Fan Motor RepairAC Capacitor Replacement
A weak run capacitor is the single most common Amana failure we see. We test microfarads on every call and replace anything reading more than 6 percent below spec.
AC Capacitor ReplacementAC Contactor Replacement
Pitted contactors cause intermittent no-cool calls and short cycling. We replace them with matched parts and check low-voltage control wiring at the same time.
AC Contactor ReplacementAC Thermostat Repair
A miscalibrated or failed thermostat makes a healthy Amana system look broken. We verify calibration, wiring, and cycle timing before condemning any equipment.
AC Thermostat RepairAC Refrigerant Leak Repair
We find leaks with an electronic detector and confirm with nitrogen pressure testing, then repair the source. Topping off refrigerant without fixing the leak just delays the next failure.
AC Refrigerant Leak RepairAC Refrigerant Recharge
Recharge is done by weight after recovery and vacuum, following the Amana charging chart. We leak-test first so you are not paying for refrigerant that will leak out again.
AC Refrigerant RechargeAC Drain Line Clog Repair
Clogged drain lines trip float switches and cause water damage. We flush the line, clear the trap, and add drain pan tablets to slow algae growth through Greenville's humid summers.
AC Drain Line Clog RepairAC Frozen Evaporator Coil Repair
Frozen coils mean restricted airflow or low charge. We thaw the coil, check the filter and blower, and verify refrigerant pressures before returning the system to service.
AC Frozen Evaporator Coil RepairAC Blowing Warm Air
Warm air usually means a capacitor, contactor, or charge problem. We test in that order and give you a flat repair price before starting work.
AC Blowing Warm AirAC Not Turning On
Breakers, float switches, contactors, and low-voltage fuses are the usual suspects. We check them in sequence and fix the actual cause, not just the symptom.
AC Not Turning OnAC Short Cycling Repair
Short cycling wears compressors and raises humidity. We check thermostat calibration, charge, and contactor condition to find why your Amana is cycling every few minutes.
AC Short Cycling RepairAC Making Strange Noises
Grinding, rattling, and screeching point to fan motor bearings, loose panels, or compressor issues. We isolate the noise source and repair it before it becomes a bigger failure.
AC Making Strange NoisesWhat Greenville customers say
Real experiences from customers who chose our Amana AC Repair services
"Our Amana was running but the house would not get below 79 degrees. The tech tested the capacitor, showed me it was reading way below spec, and swapped it out. Supply air was 20 degrees cooler when he left. He also flushed the drain line without me asking. Straightforward pricing and no pressure to replace anything."
Marcus T.
Homeowner, Nicholtown
"We manage several units with Amana systems and these guys are our first call. They diagnosed a short cycling rooftop unit as a bad contactor plus a small leak, fixed both the same day, and documented everything for the warranty. Tenants stopped calling, which is the only review that matters to me."
Dana R.
Property Manager, Haywood Road
"The outdoor unit was making a grinding noise and tripped the breaker twice. They replaced the condenser fan motor, cleaned the coil with a sprayer, and straightened the bent fins. Head pressure came back to normal and it has run quietly all summer. They also told me the filter size I should be buying, which nobody had bothered to do before."
Priya S.
Homeowner, Berea
Book Amana AC Repair in Greenville today
EPA Section 608 and NATE certified technicians, Amana parts on the truck, and upfront pricing before any work starts. Call (903) 627-1334 and we will route the closest truck to your Greenville address.